------------------------------------------------------------------------------ -- -- -- GNAT COMPILER COMPONENTS -- -- -- -- R T S F I N D -- -- -- -- B o d y -- -- -- -- Copyright (C) 1992-2006, Free Software Foundation, Inc. -- -- -- -- GNAT is free software; you can redistribute it and/or modify it under -- -- terms of the GNU General Public License as published by the Free Soft- -- -- ware Foundation; either version 2, or (at your option) any later ver- -- -- sion. GNAT is distributed in the hope that it will be useful, but WITH- -- -- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY -- -- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License -- -- for more details. You should have received a copy of the GNU General -- -- Public License distributed with GNAT; see file COPYING. If not, write -- -- to the Free Software Foundation, 51 Franklin Street, Fifth Floor, -- -- Boston, MA 02110-1301, USA. -- -- -- -- GNAT was originally developed by the GNAT team at New York University. -- -- Extensive contributions were provided by Ada Core Technologies Inc. -- -- -- ------------------------------------------------------------------------------ with Atree; use Atree; with Casing; use Casing; with Csets; use Csets; with Debug; use Debug; with Einfo; use Einfo; with Elists; use Elists; with Errout; use Errout; with Fname; use Fname; with Fname.UF; use Fname.UF; with Lib; use Lib; with Lib.Load; use Lib.Load; with Namet; use Namet; with Nlists; use Nlists; with Nmake; use Nmake; with Output; use Output; with Opt; use Opt; with Restrict; use Restrict; with Sem; use Sem; with Sem_Ch7; use Sem_Ch7; with Sem_Dist; use Sem_Dist; with Sem_Util; use Sem_Util; with Sinfo; use Sinfo; with Stand; use Stand; with Snames; use Snames; with Tbuild; use Tbuild; with Uname; use Uname; package body Rtsfind is RTE_Available_Call : Boolean := False; -- Set True during call to RTE from RTE_Available. Tells RTE to set -- RTE_Is_Available to False rather than generating an error message. RTE_Is_Available : Boolean; -- Set True by RTE_Available on entry. When RTE_Available_Call is set -- True, set False if RTE would otherwise generate an error message. ---------------- -- Unit table -- ---------------- -- The unit table has one entry for each unit included in the definition -- of the type RTU_Id in the spec. The table entries are initialized in -- Initialize to set the Entity field to Empty, indicating that the -- corresponding unit has not yet been loaded. The fields are set when -- a unit is loaded to contain the defining entity for the unit, the -- unit name, and the unit number. -- Note that a unit can be loaded either by a call to find an entity -- within the unit (e.g. RTE), or by an explicit with of the unit. In -- the latter case it is critical to make a call to Set_RTU_Loaded to -- ensure that the entry in this table reflects the load. type RT_Unit_Table_Record is record Entity : Entity_Id; Uname : Unit_Name_Type; Unum : Unit_Number_Type; Withed : Boolean; end record; RT_Unit_Table : array (RTU_Id) of RT_Unit_Table_Record; -------------------------- -- Runtime Entity Table -- -------------------------- -- There is one entry in the runtime entity table for each entity that is -- included in the definition of the RE_Id type in the spec. The entries -- are set by Initialize_Rtsfind to contain Empty, indicating that the -- entity has not yet been located. Once the entity is located for the -- first time, its ID is stored in this array, so that subsequent calls -- for the same entity can be satisfied immediately. RE_Table : array (RE_Id) of Entity_Id; -------------------------- -- Generation of WITH's -- -------------------------- -- When a unit is implicitly loaded as a result of a call to RTE, it -- is necessary to create an implicit WITH to ensure that the object -- is correctly loaded by the binder. Such WITH statements are only -- required when the request is from the extended main unit (if a -- client needs a WITH, that will be taken care of when the client -- is compiled). -- We always attach the WITH to the main unit. This is not perfectly -- accurate in terms of elaboration requirements, but it is close -- enough, since the units that are accessed using rtsfind do not -- have delicate elaboration requirements. -- The flag Withed in the unit table record is initially set to False. -- It is set True if a WITH has been generated for the main unit for -- the corresponding unit. ----------------------- -- Local Subprograms -- ----------------------- procedure Entity_Not_Defined (Id : RE_Id); -- Outputs error messages for an entity that is not defined in the -- run-time library (the form of the error message is tailored for -- no run time/configurable run time mode as required). procedure Load_Fail (S : String; U_Id : RTU_Id; Id : RE_Id); -- Internal procedure called if we can't sucessfully locate or -- process a run-time unit. The parameters give information about -- the error message to be given. S is a reason for failing to -- compile the file and U_Id is the unit id. RE_Id is the RE_Id -- originally passed to RTE. The message in S is one of the -- following: -- -- "not found" -- "had parser errors" -- "had semantic errors" -- -- The "not found" case is treated specially in that it is considered -- a normal situation in configurable run-time mode (and the message in -- this case is suppressed unless we are operating in All_Errors_Mode). function Get_Unit_Name (U_Id : RTU_Id) return Unit_Name_Type; -- Retrieves the Unit Name given a unit id represented by its -- enumeration value in RTU_Id. procedure Load_RTU (U_Id : RTU_Id; Id : RE_Id := RE_Null; Use_Setting : Boolean := False); -- Load the unit whose Id is given if not already loaded. The unit is -- loaded, analyzed, and added to the WITH list, and the entry in -- RT_Unit_Table is updated to reflect the load. Use_Setting is used -- to indicate the initial setting for the Is_Potentially_Use_Visible -- flag of the entity for the loaded unit (if it is indeed loaded). -- A value of False means nothing special need be done. A value of -- True indicates that this flag must be set to True. It is needed -- only in the Text_IO_Kludge procedure, which may materialize an -- entity of Text_IO (or [Wide_]Wide_Text_IO) that was previously unknown. -- Id is the RE_Id value of the entity which was originally requested. -- Id is used only for error message detail, and if it is RE_Null, then -- the attempt to output the entity name is ignored. procedure Output_Entity_Name (Id : RE_Id; Msg : String); -- Output continuation error message giving qualified name of entity -- corresponding to Id, appending the string given by Msg. This call -- is only effective in All_Errors mode. function RE_Chars (E : RE_Id) return Name_Id; -- Given a RE_Id value returns the Chars of the corresponding entity procedure RTE_Error_Msg (Msg : String); -- Generates a message by calling Error_Msg_N specifying Current_Error_Node -- as the node location using the given Msg text. Special processing in the -- case where RTE_Available_Call is set. In this case, no message is output -- and instead RTE_Is_Available is set to False. Note that this can only be -- used if you are sure that the message comes directly or indirectly from -- a call to the RTE function. ------------------------ -- Entity_Not_Defined -- ------------------------ procedure Entity_Not_Defined (Id : RE_Id) is begin if No_Run_Time_Mode then -- If the error occurs when compiling the body of a predefined -- unit for inlining purposes, the body must be illegal in this -- mode, and there is no point in continuing. if Is_Predefined_File_Name (Unit_File_Name (Get_Source_Unit (Sloc (Current_Error_Node)))) then Error_Msg_N ("construct not allowed in no run time mode!", Current_Error_Node); raise Unrecoverable_Error; else RTE_Error_Msg ("|construct not allowed in no run time mode"); end if; elsif Configurable_Run_Time_Mode then RTE_Error_Msg ("|construct not allowed in this configuration>"); else RTE_Error_Msg ("run-time configuration error"); end if; Output_Entity_Name (Id, "not defined"); end Entity_Not_Defined; ------------------- -- Get_Unit_Name -- ------------------- function Get_Unit_Name (U_Id : RTU_Id) return Unit_Name_Type is Uname_Chars : constant String := RTU_Id'Image (U_Id); begin Name_Len := Uname_Chars'Length; Name_Buffer (1 .. Name_Len) := Uname_Chars; Set_Casing (All_Lower_Case); if U_Id in Ada_Child then Name_Buffer (4) := '.'; if U_Id in Ada_Calendar_Child then Name_Buffer (13) := '.'; elsif U_Id in Ada_Finalization_Child then Name_Buffer (17) := '.'; elsif U_Id in Ada_Interrupts_Child then Name_Buffer (15) := '.'; elsif U_Id in Ada_Real_Time_Child then Name_Buffer (14) := '.'; elsif U_Id in Ada_Streams_Child then Name_Buffer (12) := '.'; elsif U_Id in Ada_Text_IO_Child then Name_Buffer (12) := '.'; elsif U_Id in Ada_Wide_Text_IO_Child then Name_Buffer (17) := '.'; elsif U_Id in Ada_Wide_Wide_Text_IO_Child then Name_Buffer (22) := '.'; end if; elsif U_Id in Interfaces_Child then Name_Buffer (11) := '.'; elsif U_Id in System_Child then Name_Buffer (7) := '.'; if U_Id in System_Tasking_Child then Name_Buffer (15) := '.'; end if; if U_Id in System_Tasking_Restricted_Child then Name_Buffer (26) := '.'; end if; if U_Id in System_Tasking_Protected_Objects_Child then Name_Buffer (33) := '.'; end if; if U_Id in System_Tasking_Async_Delays_Child then Name_Buffer (28) := '.'; end if; end if; -- Add %s at end for spec Name_Buffer (Name_Len + 1) := '%'; Name_Buffer (Name_Len + 2) := 's'; Name_Len := Name_Len + 2; return Name_Find; end Get_Unit_Name; ---------------- -- Initialize -- ---------------- procedure Initialize is begin -- Initialize the unit table for J in RTU_Id loop RT_Unit_Table (J).Entity := Empty; end loop; for J in RE_Id loop RE_Table (J) := Empty; end loop; RTE_Is_Available := False; end Initialize; ------------ -- Is_RTE -- ------------ function Is_RTE (Ent : Entity_Id; E : RE_Id) return Boolean is E_Unit_Name : Unit_Name_Type; Ent_Unit_Name : Unit_Name_Type; S : Entity_Id; E1 : Entity_Id; E2 : Entity_Id; begin if No (Ent) then return False; -- If E has already a corresponding entity, check it directly, -- going to full views if they exist to deal with the incomplete -- and private type cases properly. elsif Present (RE_Table (E)) then E1 := Ent; if Is_Type (E1) and then Present (Full_View (E1)) then E1 := Full_View (E1); end if; E2 := RE_Table (E); if Is_Type (E2) and then Present (Full_View (E2)) then E2 := Full_View (E2); end if; return E1 = E2; end if; -- If the unit containing E is not loaded, we already know that -- the entity we have cannot have come from this unit. E_Unit_Name := Get_Unit_Name (RE_Unit_Table (E)); if not Is_Loaded (E_Unit_Name) then return False; end if; -- Here the unit containing the entity is loaded. We have not made -- an explicit call to RTE to get the entity in question, but we may -- have obtained a reference to it indirectly from some other entity -- in the same unit, or some other unit that references it. -- Get the defining unit of the entity S := Scope (Ent); if Ekind (S) /= E_Package then return False; end if; Ent_Unit_Name := Get_Unit_Name (Unit_Declaration_Node (S)); -- If the defining unit of the entity we are testing is not the -- unit containing E, then they cannot possibly match. if Ent_Unit_Name /= E_Unit_Name then return False; end if; -- If the units match, then compare the names (remember that no -- overloading is permitted in entities fetched using Rtsfind). if RE_Chars (E) = Chars (Ent) then RE_Table (E) := Ent; -- If front-end inlining is enabled, we may be within a body that -- contains inlined functions, which has not been retrieved through -- rtsfind, and therefore is not yet recorded in the RT_Unit_Table. -- Add the unit information now, it must be fully available. declare U : RT_Unit_Table_Record renames RT_Unit_Table (RE_Unit_Table (E)); begin if No (U.Entity) then U.Entity := S; U.Uname := E_Unit_Name; U.Unum := Get_Source_Unit (S); end if; end; return True; else return False; end if; end Is_RTE; ------------ -- Is_RTU -- ------------ function Is_RTU (Ent : Entity_Id; U : RTU_Id) return Boolean is E : constant Entity_Id := RT_Unit_Table (U).Entity; begin return Present (E) and then E = Ent; end Is_RTU; ---------------------------- -- Is_Text_IO_Kludge_Unit -- ---------------------------- function Is_Text_IO_Kludge_Unit (Nam : Node_Id) return Boolean is Prf : Node_Id; Sel : Node_Id; begin if Nkind (Nam) /= N_Expanded_Name then return False; end if; Prf := Prefix (Nam); Sel := Selector_Name (Nam); if Nkind (Sel) /= N_Expanded_Name or else Nkind (Prf) /= N_Identifier or else Chars (Prf) /= Name_Ada then return False; end if; Prf := Prefix (Sel); Sel := Selector_Name (Sel); return Nkind (Prf) = N_Identifier and then (Chars (Prf) = Name_Text_IO or else Chars (Prf) = Name_Wide_Text_IO or else Chars (Prf) = Name_Wide_Wide_Text_IO) and then Nkind (Sel) = N_Identifier and then Chars (Sel) in Text_IO_Package_Name; end Is_Text_IO_Kludge_Unit; --------------- -- Load_Fail -- --------------- procedure Load_Fail (S : String; U_Id : RTU_Id; Id : RE_Id) is M : String (1 .. 100); P : Natural := 0; begin -- Output header message if Configurable_Run_Time_Mode then RTE_Error_Msg ("construct not allowed in configurable run-time mode"); else RTE_Error_Msg ("run-time library configuration error"); end if; -- Output file name and reason string if S /= "not found" or else not Configurable_Run_Time_Mode or else All_Errors_Mode then M (1 .. 6) := "\file "; P := 6; Get_Name_String (Get_File_Name (RT_Unit_Table (U_Id).Uname, Subunit => False)); M (P + 1 .. P + Name_Len) := Name_Buffer (1 .. Name_Len); P := P + Name_Len; M (P + 1) := ' '; P := P + 1; M (P + 1 .. P + S'Length) := S; P := P + S'Length; RTE_Error_Msg (M (1 .. P)); -- Output entity name Output_Entity_Name (Id, "not available"); end if; raise RE_Not_Available; end Load_Fail; -------------- -- Load_RTU -- -------------- procedure Load_RTU (U_Id : RTU_Id; Id : RE_Id := RE_Null; Use_Setting : Boolean := False) is U : RT_Unit_Table_Record renames RT_Unit_Table (U_Id); Priv_Par : constant Elist_Id := New_Elmt_List; Lib_Unit : Node_Id; procedure Save_Private_Visibility; -- If the current unit is the body of child unit or the spec of a -- private child unit, the private declarations of the parent (s) -- are visible. If the unit to be loaded is another public sibling, -- its compilation will affect the visibility of the common ancestors. -- Indicate those that must be restored. procedure Restore_Private_Visibility; -- Restore the visibility of ancestors after compiling RTU -------------------------------- -- Restore_Private_Visibility -- -------------------------------- procedure Restore_Private_Visibility is E_Par : Elmt_Id; begin E_Par := First_Elmt (Priv_Par); while Present (E_Par) loop if not In_Private_Part (Node (E_Par)) then Install_Private_Declarations (Node (E_Par)); end if; Next_Elmt (E_Par); end loop; end Restore_Private_Visibility; ----------------------------- -- Save_Private_Visibility -- ----------------------------- procedure Save_Private_Visibility is Par : Entity_Id; begin Par := Scope (Current_Scope); while Present (Par) and then Par /= Standard_Standard loop if Ekind (Par) = E_Package and then Is_Compilation_Unit (Par) and then In_Private_Part (Par) then Append_Elmt (Par, Priv_Par); end if; Par := Scope (Par); end loop; end Save_Private_Visibility; -- Start of processing for Load_RTU begin -- Nothing to do if unit is already loaded if Present (U.Entity) then return; end if; -- Note if secondary stack is used if U_Id = System_Secondary_Stack then Opt.Sec_Stack_Used := True; end if; -- Otherwise we need to load the unit, First build unit name -- from the enumeration literal name in type RTU_Id. U.Uname := Get_Unit_Name (U_Id); U.Withed := False; declare Loaded : Boolean; pragma Warnings (Off, Loaded); begin Loaded := Is_Loaded (U.Uname); end; -- Now do the load call, note that setting Error_Node to Empty is -- a signal to Load_Unit that we will regard a failure to find the -- file as a fatal error, and that it should not output any kind -- of diagnostics, since we will take care of it here. U.Unum := Load_Unit (Load_Name => U.Uname, Required => False, Subunit => False, Error_Node => Empty); if U.Unum = No_Unit then Load_Fail ("not found", U_Id, Id); elsif Fatal_Error (U.Unum) then Load_Fail ("had parser errors", U_Id, Id); end if; -- Make sure that the unit is analyzed declare Was_Analyzed : constant Boolean := Analyzed (Cunit (Current_Sem_Unit)); begin -- Pretend that the current unit is analyzed, in case it is System -- or some such. This allows us to put some declarations, such as -- exceptions and packed arrays of Boolean, into System even though -- expanding them requires System... -- This is a bit odd but works fine. If the RTS unit does not depend -- in any way on the current unit, then it never gets back into the -- current unit's tree, and the change we make to the current unit -- tree is never noticed by anyone (it is undone in a moment). That -- is the normal situation. -- If the RTS Unit *does* depend on the current unit, for instance, -- when you are compiling System, then you had better have finished -- analyzing the part of System that is depended on before you try -- to load the RTS Unit. This means having the System ordered in an -- appropriate manner. Set_Analyzed (Cunit (Current_Sem_Unit), True); if not Analyzed (Cunit (U.Unum)) then Save_Private_Visibility; Semantics (Cunit (U.Unum)); Restore_Private_Visibility; if Fatal_Error (U.Unum) then Load_Fail ("had semantic errors", U_Id, Id); end if; end if; -- Undo the pretence Set_Analyzed (Cunit (Current_Sem_Unit), Was_Analyzed); end; Lib_Unit := Unit (Cunit (U.Unum)); U.Entity := Defining_Entity (Lib_Unit); if Use_Setting then Set_Is_Potentially_Use_Visible (U.Entity, True); end if; end Load_RTU; ----------------------- -- Output_Entity_Name -- ------------------------ procedure Output_Entity_Name (Id : RE_Id; Msg : String) is M : String (1 .. 2048); P : Natural := 0; -- M (1 .. P) is current message to be output RE_Image : constant String := RE_Id'Image (Id); begin if Id = RE_Null or else not All_Errors_Mode then return; end if; M (1 .. 9) := "\entity """; P := 9; -- Add unit name to message, excluding %s or %b at end Get_Name_String (Get_Unit_Name (RE_Unit_Table (Id))); Name_Len := Name_Len - 2; Set_Casing (Mixed_Case); M (P + 1 .. P + Name_Len) := Name_Buffer (1 .. Name_Len); P := P + Name_Len; -- Add a qualifying period M (P + 1) := '.'; P := P + 1; -- Add entity name and closing quote to message Name_Len := RE_Image'Length - 3; Name_Buffer (1 .. Name_Len) := RE_Image (4 .. RE_Image'Length); Set_Casing (Mixed_Case); M (P + 1 .. P + Name_Len) := Name_Buffer (1 .. Name_Len); P := P + Name_Len; M (P + 1) := '"'; P := P + 1; -- Add message M (P + 1) := ' '; P := P + 1; M (P + 1 .. P + Msg'Length) := Msg; P := P + Msg'Length; -- Output message at current error node location RTE_Error_Msg (M (1 .. P)); end Output_Entity_Name; -------------- -- RE_Chars -- -------------- function RE_Chars (E : RE_Id) return Name_Id is RE_Name_Chars : constant String := RE_Id'Image (E); begin -- Copy name skipping initial RE_ or RO_XX characters if RE_Name_Chars (1 .. 2) = "RE" then for J in 4 .. RE_Name_Chars'Last loop Name_Buffer (J - 3) := Fold_Lower (RE_Name_Chars (J)); end loop; Name_Len := RE_Name_Chars'Length - 3; else for J in 7 .. RE_Name_Chars'Last loop Name_Buffer (J - 6) := Fold_Lower (RE_Name_Chars (J)); end loop; Name_Len := RE_Name_Chars'Length - 6; end if; return Name_Find; end RE_Chars; --------- -- RTE -- --------- function RTE (E : RE_Id) return Entity_Id is U_Id : constant RTU_Id := RE_Unit_Table (E); U : RT_Unit_Table_Record renames RT_Unit_Table (U_Id); Lib_Unit : Node_Id; Pkg_Ent : Entity_Id; Ename : Name_Id; -- The following flag is used to disable front-end inlining when RTE -- is invoked. This prevents the analysis of other runtime bodies when -- a particular spec is loaded through Rtsfind. This is both efficient, -- and it prevents spurious visibility conflicts between use-visible -- user entities, and entities in run-time packages. -- In configurable run-time mode, subprograms marked Inlined_Always must -- be inlined, so in the case we retain the Front_End_Inlining mode. Save_Front_End_Inlining : Boolean; function Check_CRT (Eid : Entity_Id) return Entity_Id; -- Check entity Eid to ensure that configurable run-time restrictions -- are met. May generate an error message and raise RE_Not_Available -- if the entity E does not exist (i.e. Eid is Empty) procedure Check_RPC; -- Reject programs that make use of distribution features not supported -- on the current target. On such targets (VMS, Vxworks, others?) we -- only provide a minimal body for System.Rpc that only supplies an -- implementation of partition_id. function Find_Local_Entity (E : RE_Id) return Entity_Id; -- This function is used when entity E is in this compilation's main -- unit. It gets the value from the already compiled declaration. function Make_Unit_Name (N : Node_Id) return Node_Id; -- If the unit is a child unit, build fully qualified name for use -- in With_Clause. --------------- -- Check_CRT -- --------------- function Check_CRT (Eid : Entity_Id) return Entity_Id is begin if No (Eid) then Entity_Not_Defined (E); raise RE_Not_Available; -- Entity is available else -- If in No_Run_Time mode and entity is not in one of the -- specially permitted units, raise the exception. if No_Run_Time_Mode and then not OK_No_Run_Time_Unit (U_Id) then Entity_Not_Defined (E); raise RE_Not_Available; end if; -- Otherwise entity is accessible return Eid; end if; end Check_CRT; --------------- -- Check_RPC -- --------------- procedure Check_RPC is begin -- Bypass this check if debug flag -gnatdR set if Debug_Flag_RR then return; end if; -- Otherwise we need the check if we are going after one of -- the critical entities in System.RPC in stubs mode. -- ??? Should we do this for other s-parint/s-polint entities -- too? if (Distribution_Stub_Mode = Generate_Receiver_Stub_Body or else Distribution_Stub_Mode = Generate_Caller_Stub_Body) and then (E = RE_Do_Rpc or else E = RE_Do_Apc or else E = RE_Params_Stream_Type or else E = RE_Request_Access) and then Get_PCS_Name = Name_No_DSA then Set_Standard_Error; Write_Str ("distribution feature not supported"); Write_Eol; raise Unrecoverable_Error; end if; end Check_RPC; ------------------------ -- Find_System_Entity -- ------------------------ function Find_Local_Entity (E : RE_Id) return Entity_Id is RE_Str : String renames RE_Id'Image (E); Ent : Entity_Id; Save_Nam : constant String := Name_Buffer (1 .. Name_Len); -- Save name buffer and length over call begin Name_Len := Natural'Max (0, RE_Str'Length - 3); Name_Buffer (1 .. Name_Len) := RE_Str (RE_Str'First + 3 .. RE_Str'Last); Ent := Entity_Id (Get_Name_Table_Info (Name_Find)); Name_Len := Save_Nam'Length; Name_Buffer (1 .. Name_Len) := Save_Nam; return Ent; end Find_Local_Entity; -------------------- -- Make_Unit_Name -- -------------------- function Make_Unit_Name (N : Node_Id) return Node_Id is Nam : Node_Id; Scop : Entity_Id; begin Nam := New_Reference_To (U.Entity, Standard_Location); Scop := Scope (U.Entity); if Nkind (N) = N_Defining_Program_Unit_Name then while Scop /= Standard_Standard loop Nam := Make_Expanded_Name (Standard_Location, Chars => Chars (U.Entity), Prefix => New_Reference_To (Scop, Standard_Location), Selector_Name => Nam); Set_Entity (Nam, U.Entity); Scop := Scope (Scop); end loop; end if; return Nam; end Make_Unit_Name; -- Start of processing for RTE begin -- Doing a rtsfind in system.ads is special, as we cannot do this -- when compiling System itself. So if we are compiling system then -- we should already have acquired and processed the declaration -- of the entity. The test is to see if this compilation's main unit -- is System. If so, return the value from the already compiled -- declaration and otherwise do a regular find. -- Not pleasant, but these kinds of annoying recursion when -- writing an Ada compiler in Ada have to be broken somewhere! if Present (Main_Unit_Entity) and then Chars (Main_Unit_Entity) = Name_System and then Analyzed (Main_Unit_Entity) and then not Is_Child_Unit (Main_Unit_Entity) then return Check_CRT (Find_Local_Entity (E)); end if; Save_Front_End_Inlining := Front_End_Inlining; Front_End_Inlining := Configurable_Run_Time_Mode; -- Load unit if unit not previously loaded if No (RE_Table (E)) then Load_RTU (U_Id, Id => E); Lib_Unit := Unit (Cunit (U.Unum)); -- In the subprogram case, we are all done, the entity we want -- is the entity for the subprogram itself. Note that we do not -- bother to check that it is the entity that was requested. -- the only way that could fail to be the case is if runtime is -- hopelessly misconfigured, and it isn't worth testing for this. if Nkind (Lib_Unit) = N_Subprogram_Declaration then RE_Table (E) := U.Entity; -- Otherwise we must have the package case. First check package -- entity itself (e.g. RTE_Name for System.Interrupts.Name) else pragma Assert (Nkind (Lib_Unit) = N_Package_Declaration); Ename := RE_Chars (E); -- First we search the package entity chain Pkg_Ent := First_Entity (U.Entity); while Present (Pkg_Ent) loop if Ename = Chars (Pkg_Ent) then RE_Table (E) := Pkg_Ent; Check_RPC; goto Found; end if; Next_Entity (Pkg_Ent); end loop; -- If we did not find the entity in the package entity chain, -- then check if the package entity itself matches. Note that -- we do this check after searching the entity chain, since -- the rule is that in case of ambiguity, we prefer the entity -- defined within the package, rather than the package itself. if Ename = Chars (U.Entity) then RE_Table (E) := U.Entity; end if; -- If we didn't find the entity we want, something is wrong. -- We just leave RE_Table (E) set to Empty and the appropriate -- action will be taken by Check_CRT when we exit. end if; end if; -- See if we have to generate a WITH for this entity. We generate -- a WITH if the current unit is part of the extended main code -- unit, and if we have not already added the with. The WITH is -- added to the appropriate unit (the current one). We do not need -- to generate a WITH for an ???? <> if (not U.Withed) and then In_Extended_Main_Code_Unit (Cunit_Entity (Current_Sem_Unit)) and then not RTE_Available_Call then U.Withed := True; declare Withn : Node_Id; Lib_Unit : Node_Id; begin Lib_Unit := Unit (Cunit (U.Unum)); Withn := Make_With_Clause (Standard_Location, Name => Make_Unit_Name (Defining_Unit_Name (Specification (Lib_Unit)))); Set_Library_Unit (Withn, Cunit (U.Unum)); Set_Corresponding_Spec (Withn, U.Entity); Set_First_Name (Withn, True); Set_Implicit_With (Withn, True); Mark_Rewrite_Insertion (Withn); Append (Withn, Context_Items (Cunit (Current_Sem_Unit))); Check_Restriction_No_Dependence (Name (Withn), Current_Error_Node); end; end if; Front_End_Inlining := Save_Front_End_Inlining; return Check_CRT (RE_Table (E)); end RTE; ------------------- -- RTE_Available -- ------------------- function RTE_Available (E : RE_Id) return Boolean is Dummy : Entity_Id; pragma Warnings (Off, Dummy); Result : Boolean; Save_RTE_Available_Call : constant Boolean := RTE_Available_Call; Save_RTE_Is_Available : constant Boolean := RTE_Is_Available; -- These are saved recursively because the call to load a unit -- caused by an upper level call may perform a recursive call -- to this routine during analysis of the corresponding unit. begin RTE_Available_Call := True; RTE_Is_Available := True; Dummy := RTE (E); Result := RTE_Is_Available; RTE_Available_Call := Save_RTE_Available_Call; RTE_Is_Available := Save_RTE_Is_Available; return Result; exception when RE_Not_Available => RTE_Available_Call := Save_RTE_Available_Call; RTE_Is_Available := Save_RTE_Is_Available; return False; end RTE_Available; ------------------- -- RTE_Error_Msg -- ------------------- procedure RTE_Error_Msg (Msg : String) is begin if RTE_Available_Call then RTE_Is_Available := False; else Error_Msg_N (Msg, Current_Error_Node); -- Bump count of violations if we are in configurable run-time -- mode and this is not a continuation message. if Configurable_Run_Time_Mode and then Msg (1) /= '\' then Configurable_Run_Time_Violations := Configurable_Run_Time_Violations + 1; end if; end if; end RTE_Error_Msg; ---------------- -- RTU_Loaded -- ---------------- function RTU_Loaded (U : RTU_Id) return Boolean is begin return Present (RT_Unit_Table (U).Entity); end RTU_Loaded; -------------------- -- Set_RTU_Loaded -- -------------------- procedure Set_RTU_Loaded (N : Node_Id) is Loc : constant Source_Ptr := Sloc (N); Unum : constant Unit_Number_Type := Get_Source_Unit (Loc); Uname : constant Unit_Name_Type := Unit_Name (Unum); E : constant Entity_Id := Defining_Entity (Unit (Cunit (Unum))); begin pragma Assert (Is_Predefined_File_Name (Unit_File_Name (Unum))); -- Loop through entries in RTU table looking for matching entry for U_Id in RTU_Id'Range loop -- Here we have a match if Get_Unit_Name (U_Id) = Uname then declare U : RT_Unit_Table_Record renames RT_Unit_Table (U_Id); -- The RT_Unit_Table entry that may need updating begin -- If entry is not set, set it now if No (U.Entity) then U.Entity := E; U.Uname := Get_Unit_Name (U_Id); U.Unum := Unum; U.Withed := False; end if; return; end; end if; end loop; end Set_RTU_Loaded; -------------------- -- Text_IO_Kludge -- -------------------- procedure Text_IO_Kludge (Nam : Node_Id) is Chrs : Name_Id; type Name_Map_Type is array (Text_IO_Package_Name) of RTU_Id; Name_Map : constant Name_Map_Type := Name_Map_Type'( Name_Decimal_IO => Ada_Text_IO_Decimal_IO, Name_Enumeration_IO => Ada_Text_IO_Enumeration_IO, Name_Fixed_IO => Ada_Text_IO_Fixed_IO, Name_Float_IO => Ada_Text_IO_Float_IO, Name_Integer_IO => Ada_Text_IO_Integer_IO, Name_Modular_IO => Ada_Text_IO_Modular_IO); Wide_Name_Map : constant Name_Map_Type := Name_Map_Type'( Name_Decimal_IO => Ada_Wide_Text_IO_Decimal_IO, Name_Enumeration_IO => Ada_Wide_Text_IO_Enumeration_IO, Name_Fixed_IO => Ada_Wide_Text_IO_Fixed_IO, Name_Float_IO => Ada_Wide_Text_IO_Float_IO, Name_Integer_IO => Ada_Wide_Text_IO_Integer_IO, Name_Modular_IO => Ada_Wide_Text_IO_Modular_IO); Wide_Wide_Name_Map : constant Name_Map_Type := Name_Map_Type'( Name_Decimal_IO => Ada_Wide_Wide_Text_IO_Decimal_IO, Name_Enumeration_IO => Ada_Wide_Wide_Text_IO_Enumeration_IO, Name_Fixed_IO => Ada_Wide_Wide_Text_IO_Fixed_IO, Name_Float_IO => Ada_Wide_Wide_Text_IO_Float_IO, Name_Integer_IO => Ada_Wide_Wide_Text_IO_Integer_IO, Name_Modular_IO => Ada_Wide_Wide_Text_IO_Modular_IO); begin -- Nothing to do if name is not identifier or a selected component -- whose selector_name is not an identifier. if Nkind (Nam) = N_Identifier then Chrs := Chars (Nam); elsif Nkind (Nam) = N_Selected_Component and then Nkind (Selector_Name (Nam)) = N_Identifier then Chrs := Chars (Selector_Name (Nam)); else return; end if; -- Nothing to do if name is not one of the Text_IO subpackages -- Otherwise look through loaded units, and if we find Text_IO -- or [Wide_]Wide_Text_IO already loaded, then load the proper child. if Chrs in Text_IO_Package_Name then for U in Main_Unit .. Last_Unit loop Get_Name_String (Unit_File_Name (U)); if Name_Len = 12 then -- Here is where we do the loads if we find one of the units -- Ada.Text_IO or Ada.[Wide_]Wide_Text_IO. An interesting -- detail is that these units may already be used (i.e. their -- In_Use flags may be set). Normally when the In_Use flag is -- set, the Is_Potentially_Use_Visible flag of all entities in -- the package is set, but the new entity we are mysteriously -- adding was not there to have its flag set at the time. So -- that's why we pass the extra parameter to RTU_Find, to make -- sure the flag does get set now. Given that those generic -- packages are in fact child units, we must indicate that -- they are visible. if Name_Buffer (1 .. 12) = "a-textio.ads" then Load_RTU (Name_Map (Chrs), Use_Setting => In_Use (Cunit_Entity (U))); Set_Is_Visible_Child_Unit (RT_Unit_Table (Name_Map (Chrs)).Entity); elsif Name_Buffer (1 .. 12) = "a-witeio.ads" then Load_RTU (Wide_Name_Map (Chrs), Use_Setting => In_Use (Cunit_Entity (U))); Set_Is_Visible_Child_Unit (RT_Unit_Table (Wide_Name_Map (Chrs)).Entity); elsif Name_Buffer (1 .. 12) = "a-ztexio.ads" then Load_RTU (Wide_Wide_Name_Map (Chrs), Use_Setting => In_Use (Cunit_Entity (U))); Set_Is_Visible_Child_Unit (RT_Unit_Table (Wide_Wide_Name_Map (Chrs)).Entity); end if; end if; end loop; end if; end Text_IO_Kludge; end Rtsfind;